Seasonic Prime Platinum 650W

Brand Seasonic
Product name Prime Platinum 650W
Productserie Prime Platinum
Productgroep Power supplies
MPN SSR-650PD
EAN / UPC 4711173873440
All power supplies

650 W, 94 %, 80 Plus Platinum, Modular, 54 A

Seasonic Prime Platinum 650W test results

Expand all specifications

Test results - HWI PSU test setup 2009 Show charts of test results
  0W Test - PSU Off - Power consumption (W) 0.00 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  0W Test - PSU On - Power consumption (W) 0.20 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 3,3V 3.31 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 5V 5 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 12V 12.11 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 12V Max. ripple 3 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - Efficiency 71.2 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 3,3V 3.31 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 5V 4.99 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 12V2 12.1 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 12V Max. ripple 4.6 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - Efficiency 83.7 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 3,3V 3.30 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 5V 4.98 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 12V2 12.09 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 12V Max. ripple 6 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - Efficiency 89.8 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 3.3V 3.29 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 5V 4.97 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 12V2 12.09 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 12V Max. ripple 8.4 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - Efficiency 88.79 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 3.3V 3.28 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 5V 4.96 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 12V2 12.08 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 12V Max. ripple 9.6 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - Efficiency 89.00 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 3.3V 3.28 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 5V 4.95 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 12V2 12.07 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 12V Max. ripple 7.8 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - Efficiency 89.62 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 3.3V 3.28 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 5V 4.94 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 12V2 12.06 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 12V Max. ripple 8.2 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - Efficiency 89.85 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  600W Test - 3.3V 3.27 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  600W Test - 5V 4.92 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  600W Test - 12V2 12.05 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  600W Test - 12V Max. ripple 11.4 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  600W Test - Efficiency 89.60 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Maximum stable load +/- 100W 650 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Average efficiency (200W - max load) 89.37 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Noise test - ca. 100W Load - 10 cm. - after 5 min. 20 dB(A)

Test configuration

Bruël & Kjaer 2238 sound meter in sound proof box, measured at 10 cm. distance.

  Noise test - ca. 300W Load - 10 cm. - after 5 min. 19 dB(A)

Test configuration

Bruël & Kjaer 2238 sound meter in sound proof box, measured at 10 cm. distance.

  Noise test - ca. 500W Load - 10 cm.- after 20 min. 37 dB(A)

Test configuration

Bruël & Kjaer 2238 sound meter in sound proof box, measured at 10 cm. distance.

This product has been tested by Hardware.Info on Thursday 20 April 2017.

The Hardware.Info website uses cookies.
*