Corsair RM550x

All power supplies
Brand Corsair
Product name RM550x
Productgroep Power supplies
MPN CP-9020090-
CP-9020090-EU
CP-9020090-UK
EAN / UPC 0843591050555
8435910505550

550 W, 92 %, 80 Plus Gold, Modular, 45.8 A

Corsair RM550x test results

Expand all specifications

Test results - HWI PSU test setup 2009 Show charts of test results
  0W Test - PSU Off - Power consumption (W) 0.00 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  0W Test - PSU On - Power consumption (W) 0.10 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 3,3V 3.29 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 5V 5 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 12V 12.05 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - 12V Max. ripple 2 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  22,5W Test - Efficiency 72.6 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 3,3V 3.28 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 5V 5 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 12V2 12.04 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - 12V Max. ripple 2.2 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  50W Test - Efficiency 84.1 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 3,3V 3.28 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 5V 4.99 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 12V2 12.03 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - 12V Max. ripple 2.8 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  100W Test - Efficiency 89.5 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 3.3V 3.26 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 5V 4.96 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 12V2 12.02 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 12V Max. ripple 4.2 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - Efficiency 88.13 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 3.3V 3.26 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 5V 4.96 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 12V2 12.00 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 12V Max. ripple 5.2 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - Efficiency 89.06 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 3.3V 3.26 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 5V 4.94 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 12V2 11.99 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 12V Max. ripple 5.6 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - Efficiency 89.61 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 3.3V 3.25 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 5V 4.93 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 12V2 11.97 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - 12V Max. ripple 6.6 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  500W Test - Efficiency 89.62 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Maximum stable load +/- 100W 500 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Average efficiency (200W - max load) 89.11 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Noise test - ca. 100W Load - 10 cm. - after 5 min. 18 dB(A)

Test configuration

Bruël & Kjaer 2238 sound meter in sound proof box, measured at 10 cm. distance.

  Noise test - ca. 300W Load - 10 cm. - after 5 min. 20 dB(A)

Test configuration

Bruël & Kjaer 2238 sound meter in sound proof box, measured at 10 cm. distance.

  Noise test - ca. 500W Load - 10 cm.- after 20 min. 25 dB(A)

Test configuration

Bruël & Kjaer 2238 sound meter in sound proof box, measured at 10 cm. distance.

This product has been tested by Hardware.Info on Thursday 24 September 2015.

The Hardware.Info website uses cookies.
*