Corsair CX430 V3

Brand Corsair
Product name CX430 V3
Productgroep Power supplies
MPN CP-9020046-
CP-9020046-EU
CP-9020046-UK
EAN / UPC 0843591029308
0843591029322
5053460857429
All power supplies

430 W, 80 %, 80 Plus Bronze, 32 A

Corsair CX430 V3 test results

Expand all specifications

Test results - HWI PSU test setup 2009 Show charts of test results
  0W Test - PSU Off - Power consumption (W) 0.00 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  0W Test - PSU On - Power consumption (W) 0.20 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 3.3V 3.26 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 5V 5.04 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 12V2 12.01 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - 12V Max. ripple 35.2 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  200W Test - Efficiency 84.51 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 3.3V 3.25 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 5V 5.05 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 12V2 11.96 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - 12V Max. ripple 38.04 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  300W Test - Efficiency 84.46 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 3.3V 3.23 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 5V 5.07 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 12V2 11.83 V

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - 12V Max. ripple 41.6 mVtt

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  400W Test - Efficiency 83.53 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Maximum stable load +/- 100W 400 W

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Average efficiency (200W - max load) 84.17 %

Test configuration

HWI Power Supply testrig (6x Statron 3229 load generator)

  Noise test - ca. 100W Load - 10 cm. - after 5 min. 32 dB(A)

Test configuration

Bruël & Kjaer 2238 sound meter in sound proof box, measured at 10 cm. distance.

This product has been tested by Hardware.Info on Friday 18 January 2013.

The Hardware.Info website uses cookies.
*